Solar Physics & Hardware

State of Charge (SoC)

State of charge (SoC) is the energy left in a battery as a percentage of its usable capacity: 100 percent is full, 0 percent is empty. Batteries are run within a set SoC window, and the share held back as a reserve decides how much capacity is left for daily solar storage.

Also known asSoCBattery state of chargeCharge levelDepth of dischargeDoD

State of charge (SoC) is a battery's fuel gauge. It expresses the energy currently stored as a percentage of the battery's capacity, from 0 percent when empty to 100 percent when full. Its mirror image is depth of discharge (DoD), the share of capacity that has been used.

The usable window is narrower than the nameplate. Battery management systems keep the SoC above a minimum to protect the cells and sometimes below a maximum to slow ageing. The energy a battery can actually shift each day is what lies between those limits, which is why usable capacity matters more than nominal capacity.

A reserve takes capacity out of daily use. Many solar batteries keep part of their capacity as a backup reserve for grid outages. That energy stays in the battery on normal days, so it buys resilience but does not store any midday surplus.

SoC follows the hours. Over a day the SoC rises while solar output exceeds the load, falls in the evening, and stays wherever the night leaves it until the sun returns. A battery that is already full by 11:00 is undersized for the surplus; one that rarely gets above half is oversized.

Why it matters for solar installers

Whether a battery pays back depends on how much of its capacity actually cycles. SolarVis sizes the battery automatically and runs an hourly simulation with a state-of-charge range and a configurable backup percentage, then reports backup time and backup capacity alongside the savings. See battery modeling.

Common questions

What is the difference between state of charge and depth of discharge?
They describe the same thing from opposite ends. State of charge is how full the battery is; depth of discharge is how much of its capacity has been used. A battery at 30 percent SoC has a depth of discharge of 70 percent.
Why is a solar battery not run from 0 to 100 percent?
Most battery systems keep a minimum SoC to protect the cells and often a maximum below 100 percent, and many users reserve part of the capacity for backup during a grid outage. The capacity the battery actually cycles each day is only what lies between those limits.
How does a backup reserve affect savings?
Capacity held as a backup reserve is not available for storing the midday surplus, so it adds resilience but not daily savings. A 10 kWh battery with a 30 percent reserve cycles at most 7 kWh a day, and the payback calculation has to use that figure.

Put this to work in solarVis

Further reading

Last updated November 10, 2026
Get started

See solarVis in action

We use cookies to improve solarVis

Necessary cookies keep the site running. Analytics and marketing cookies show us which pages actually help installers and let us measure our ads. We enable analytics and marketing cookies by default to improve this site and measure our ads. You can opt out anytime. Read our Cookie Policy