NOCT (Nominal Operating Cell Temperature)
NOCT, the nominal operating cell temperature, is the temperature a solar module's cells reach under defined field-like conditions: 800 W/m² of irradiance, 20 °C air and 1 m/s wind. Together with the temperature coefficients, it shows how much power a module loses to heat on a real roof.
NOCT, the nominal operating cell temperature, describes how hot a solar module's cells get in normal outdoor operation. It is measured with the module open-rack mounted under 800 W/m² of irradiance, 20 °C ambient air and a 1 m/s wind. The cell temperature it settles at, typically in the 40s °C for crystalline modules, is printed on the datasheet together with the module's power at those conditions.
It exists because STC is unrealistic. A module's rated power is measured under Standard Test Conditions with the cells held at 25 °C. In the sun, cells run 20 to 30 °C above the air temperature, so the STC rating overstates real output. NOCT gives a more representative operating point.
The temperature coefficients do the rest. Datasheets list how power, voltage and current change per °C. Power typically falls by around 0.3 to 0.4 percent per °C above 25 °C, and voltage falls with it, while current rises slightly. These coefficients turn a cell temperature into a power loss, and they are also what raise a string's open-circuit voltage on cold mornings.
NMOT is the newer name. The current IEC 61215 standard measures the nominal module operating temperature (NMOT) with the module under load. It is close to NOCT and many datasheets now print it instead.
Why it matters for solar installers
Heat is one of the largest losses on a summer roof, and it varies with mounting, ventilation and climate. SolarVis computes yield with a physics-based electrical model that uses each module's datasheet parameters, temperature coefficients included, so heat losses and cold-weather string voltages come from the module the customer is buying. See 3D design and simulation.
Common questions
- What is the difference between STC and NOCT?
- Standard Test Conditions rate a module at 1,000 W/m² with the cell held at 25 °C, a laboratory point. NOCT describes a module in more realistic conditions, 800 W/m², 20 °C air and 1 m/s wind, and reports the cell temperature it settles at, typically in the 40 to 47 °C range for crystalline modules.
- What is NMOT?
- NMOT, the nominal module operating temperature, is the successor to NOCT in the current IEC 61215 standard. It is measured under similar conditions but with the module under electrical load, so it is usually a little lower than NOCT. Many datasheets now print NMOT instead of, or next to, NOCT.
- How does temperature affect solar module output?
- A crystalline module typically loses around 0.3 to 0.4 percent of its power for every °C its cells run above 25 °C, the temperature coefficient of Pmax on the datasheet. A cell at 50 °C on a summer roof can therefore deliver around a tenth less than its rated power.