Kilowatt Peak (kWp)
Kilowatt peak (kWp) is the rated DC power of a solar array under Standard Test Conditions: 1,000 W/m² of irradiance at a cell temperature of 25 °C. It is the unit used to size, compare and price PV systems, not a measure of how much power the system delivers on a real day.
Kilowatt peak (kWp) is the nameplate power of a solar array. It is the sum of the rated power of its modules, each measured under Standard Test Conditions (STC): 1,000 W/m² of irradiance, a cell temperature of 25 °C and an air mass of 1.5. Twenty 450 W modules make a 9 kWp array.
It is a laboratory rating. STC is a reference point that makes modules comparable, not a description of a real roof. Cells on a sunny roof run well above 25 °C, which lowers their voltage and output, and irradiance reaches 1,000 W/m² only around midday on clear days. So a 10 kWp array almost never delivers 10 kW.
It is the unit the industry trades in. Systems are sized, quoted and financed in kWp, and price-per-kWp benchmarks use it. Grid connection rules, by contrast, are often set in AC power or current, so the inverter rating counts there as well. In France the same unit is written kWc (kilowatt-crête).
It is not energy. What a customer pays for is kWh, the energy the array produces over a year. Dividing that annual energy by the kWp gives the specific yield, which is how arrays in different places are compared.
Why it matters for solar installers
kWp is where sizing starts, but a proposal sold on kWp alone invites comparison on price alone. SolarVis sizes the array against the roof and the hourly consumption, simulates the yield those kWp produce on that site, and reports the system price per kWp alongside payback and annual savings, so the customer sees what the capacity is worth. See 3D design and simulation.
Common questions
- Does a 10 kWp system produce 10 kW?
- Rarely. The rating assumes 1,000 W/m² of irradiance and a 25 °C cell, conditions a roof seldom sees. Real output is lower because of heat, orientation, shading, soiling and conversion losses, and the inverter may limit it further. The kWp figure describes the array, not its output at any given moment.
- What is the difference between kWp and kWh?
- kWp is power capacity, the size of the array. kWh is energy, the amount produced over time. A 10 kWp array might produce around 9,000 to 11,000 kWh a year in central Europe and considerably more in a sunnier climate.
- What is price per kWp?
- The total system price divided by the array's peak power. It lets buyers compare quotes for systems of different sizes and lets installers check that a quote sits within the market range, although it says nothing about yield or component quality.