DC/AC Ratio

The DC/AC ratio is the array's DC peak power divided by the inverter's AC rated power. A 12 kWp array on a 10 kW inverter has a ratio of 1.2. Most systems are oversized on purpose, because the array rarely reaches its peak rating and a slightly smaller inverter loses little energy to clipping.

Also known asDC to AC ratioInverter loading ratioILRInverter oversizingArray-to-inverter ratio

The DC/AC ratio, also called the inverter loading ratio, compares the size of the solar array with the size of the inverter. It is the array's peak power in kWp divided by the inverter's rated AC power in kW. An array of 12 kWp on a 10 kW inverter has a DC/AC ratio of 1.2.

Oversizing is normal. A module produces its rated power only under Standard Test Conditions, and on a real roof heat, irradiance and losses keep it below that most of the time. An inverter sized exactly to the array would therefore run below its rating almost all year. A slightly smaller inverter costs less and works closer to its efficient range.

Clipping is the price. On the brightest hours, when the array could deliver more than the inverter's AC rating, the inverter caps its output and the surplus is lost. With a moderate ratio this affects a few midday hours a year. With an aggressive ratio the losses grow quickly.

The DC limits still apply. Oversizing the array relative to the AC rating is fine. Exceeding the inverter's DC input voltage or MPPT current is not, which is why the ratio is always checked together with the string design.

Why it matters for solar installers

The DC/AC ratio is a trade-off between inverter cost and lost energy, and it is different for every site. SolarVis scores inverter suggestions on their distance from an optimum DC/AC ratio and computes yield per string, per MPPT and per inverter, including clipping, so the chosen ratio is backed by the simulated output. See 3D design and simulation.

Common questions

What is a good DC/AC ratio?
Many residential and commercial systems land between about 1.1 and 1.3. The right figure depends on climate, orientation and the inverter price: a cool, cloudy site or an east-west array can take a higher ratio than a hot, south-facing one before clipping losses outweigh the saving.
What is inverter clipping?
When the array could deliver more power than the inverter's AC rating, the inverter limits its output to that rating and the surplus is lost. On an oversized system this happens only around midday on the brightest days, so the annual energy lost is usually small.
Is a DC/AC ratio above 1 safe for the inverter?
Yes, as long as the strings stay inside the inverter's DC input limits, above all the maximum input voltage and the MPPT current. The inverter caps its own AC output; it is exceeding the DC voltage or current limits that damages it.