Open-Circuit Voltage (Voc)
Open-circuit voltage (Voc) is the voltage a solar module or string produces when no current flows, the highest voltage it can reach. It rises as the cells get colder, so a string's Voc on the coldest morning of the year sets the maximum number of modules allowed in series on an inverter input.
Open-circuit voltage (Voc) is the voltage across a solar module, or a string of modules, when its terminals are not connected to a load and no current flows. It is the highest voltage the module can produce, and it appears on every datasheet at Standard Test Conditions.
It is the limit that protects the inverter. Modules in series add their voltages. Every inverter has a maximum DC input voltage, and a string whose Voc exceeds it can damage the inverter or trip it off. Voc, not the operating voltage, is what the string has to stay under.
Cold raises it. A cell's voltage increases as its temperature falls. The worst case is a clear winter morning: the cells are cold, the sun is already on them, and the inverter has not yet started drawing current. The string's Voc at that moment, corrected with the module's temperature coefficient, is what sizing has to check against.
It works with the other limits. Voc sets the maximum string length. The voltage at maximum power (Vmp) on a hot day sets the minimum, because it must stay inside the MPPT window. The current limit of each MPPT input sets how many strings can run in parallel.
Why it matters for solar installers
A string that is one module too long can work all summer and fail on the first frosty morning. SolarVis computes string voltage from temperature-corrected module values and flags a string Voc above the inverter's input limit or a Vmp below its minimum, on the design and on the generated single line diagram. See single line diagram.
Common questions
- Why does Voc increase in cold weather?
- A solar cell's voltage falls as its temperature rises and rises as it falls. Datasheets give this as a temperature coefficient of Voc, typically around minus 0.25 to minus 0.3 percent per °C for crystalline modules. On a cold, bright morning the cells are far below 25 °C, so the string voltage is above its datasheet value.
- How do you calculate the maximum string length from Voc?
- Correct the module's Voc to the lowest expected cell temperature with its temperature coefficient, multiply by the number of modules in series, and keep the result below the inverter's maximum DC input voltage. The largest module count that stays below the limit is the maximum string length.
- What is the difference between Voc and Vmp?
- Voc is the voltage with no current flowing. Vmp is the voltage at the maximum power point, where the module actually operates in normal service. Voc sets the upper limit for safety; Vmp has to stay inside the inverter's MPPT range so the string is tracked efficiently.